aUTOMATIONS

MM20 Milk Meter

The MM20 milk meter includes milk yield measurement (± 5%), conductivity measurement and milking time. It connects to the Micro M5 parlour control and Cowculator M5 PC software.

Control Features
Simple numeric display of milk yield (litres), milking time (minutes:seconds) and highest conductivity (mS – millisiemens).
4 keys – automatic milking, manual milking, wash and conductivity on/off.
Simple, bright OLED display
5 LED windows for auto milking, pulsation, ACR, milk flow and conductivity milking.
2 windows with multiple LEDs graphically displaying conductivity level.
2 automatic milking modes – 1 time-based cluster removal and 1 sensor-based cluster removal.
3 manual milking modes (ACR disabled, conductivity pull off disabled, ACR and conductivity disabled).
Accurate milk yield measurement (± 5%).
Accurate milk flow measurement for ACR removal.
Full pulsation control – 30 to 180 pulses per minute (ppm) and 35% to 75% ratios including pulsation stop – pulsator only on when milking or washing.
Stimulation pulsation.
Washing pulsation – runs pulsation frequency t lower rate during washing to reduce liner wear.
User programmable wash time.
Wash time elapsed and remaining displayed (minutes:seconds).
User set conductivity warning and pull off levels
User selectable ACR pull off milk flow and time.
Lift to start ACR input / swing to start input.
Automatic idle after user selectable period of inactivity.
Milk sweep / purge.
Small form factor, allowing for easy installation into existing parlours.
Suitable for all herd / flock sizes of cows, sheep and goats.
Suitable for abreast, tandem, herringbone, parallel or rotary parlours.
Ability to lower clusters below the bridge on rotary parlours.
Total litres of milk measured per milking for each milk meter can be displayed and added together to easily check calibration.
Upgrade Features
These features are available if the MM20 controls are upgraded to connect to the Micro M5 parlour control system.
M2 communications bus link to ATL system – includes activation of LED signalling bus functioning in bottom left of MM20 control.
Sending of animal numbers and warning flags to MM20 control – operator can only acknowledge warnings – they cannot set them on the MM20 control – to do this they have to use the Micro M5 parlour control.
Sending of milk yield, milking time and conductivity information to Micro M5.
Flask Features
Manufactured from polysulfone for excellent mechanical strength and chemical and temperature resistance.
Dumping milk meter – plunger on diaphragm lift to open outlet and empty milk when milk reaches top probe. It then falls to close outlet and enable flask to fill with milk again.
Each dump is approximately 200ml.
Milk Inlet – 15mm ID, 19mm OD.
Milk Outlet – 18mm ID, 22mm OD.
No electronic parts with milk meter – simple design ensures low service costs.

Want to learn more?

Download the product PDF Leaflet here

DOWNLOAD

Download the product PDF Manual here

DOWNLOAD

Not found what you're looking for?